Sciencell

GeneQuery™ Human Chondrocyte Channels and Receptors qPCR Array Kit

Product Code:
 
SC-GK068
Product Group:
 
PCR Kits
Supplier:
 
Sciencell
Host Type:
 
Human
Regulatory Status:
 
RUO
1 / 1

No additional charges, what you see is what you pay! *

CodeSizePrice
SC-GK0681 kit£297.00
Please contact us with your Instrument Model Type to ensure ordering of the correct kit version.
Quantity:
Prices exclude any Taxes / VAT
Stay in control of your spending. These prices have no additional charges, not even shipping!
* Rare exceptions are clearly labelled (only 0.14% of items!).
Multibuy discounts available! Contact us to find what you can save.
This product comes from: United States.
Typical lead time: 10-14 working days.
Contact us for more accurate information.
  • Further Information
  • Documents
  • Show All

Further Information

Description:
The primary function of chondrocytes is to synthesize and secrete cartilage matrix during injury and repair. To perform this task, chondrocytes need to sense changes in their surrounding cartilage ECM, therefore chondrocyte mechanotransduction is a key component of healthy articular cartilage function. ScienCell's GeneQuery™ Human Chondrocyte Channels and Receptors qPCR Array (GQH-CCR) facilitates gene expression profiling of 88 channels and receptors involved in chondrocyte mechanotransduction and environment sensing. Brief examples of how included genes may be grouped according to channel or receptor type are shown below:
  • Potassium Channels: - KCNA4, KCNJ8, KCNK5, ABCC9, ABCC8
  • Chloride Channels: - ANO1, ANO3, ANO5, CFTR, CLCN3
  • G protein-coupled receptors: - HRH1, PTGER1, ADORA2A, P2RX1, P2RY1
  • NMDA receptors: - GRIN1, GRIN2A, GRIN2B, GRIN2D
  • Chemokine receptors: - CCR1, CCR2, CCR5, CXCR1, CXCR2
GeneQuery™ qPCR array kits are qPCR ready in a 96-well plate format, with each well containing one primer set that recognizes and efficiently amplifies a specific target gene's cDNA. The carefully designed primers ensure that: (i) the optimal annealing temperature in qPCR analysis is 65°C (with 2 mM Mg^2+ and no DMSO); (ii) the primer set recognizes all known transcript variants of the target gene, unless otherwise noted; and (iii) only one gene is amplified. Each primer set has been validated by qPCR with melt curve analysis and gel electrophoresis.
Extra Description:
The carefully designed primers ensure that: (i) the optimal annealing temperature in qPCR analysis is 65°C (with 2 mM Mg2+ and no DMSO); (ii) the primer set recognizes all known transcript variants of the target gene, unless otherwise noted; and (iii) only one gene is amplified.