Cloud-Clone Corp.

Multiplex?Assay?Kit?for?Mab21 Domain Containing Protein 1 (MB21D1)

Product Code:
 
LMU056Mu
Product Group:
 
Multiplex Kits
Supplier:
 
Cloud-Clone Corp.
Host Type:
 
Mouse
Regulatory Status:
 
RUO
 

No additional charges, what you see is what you pay! *

CodeSizePrice
LMU056Mu-96T96T£606.00
Quantity:
Prices exclude any Taxes / VAT
Stay in control of your spending. These prices have no additional charges to UK mainland customers, not even shipping!
* Rare exceptions are clearly labelled (only 0.14% of items!).
Multibuy discounts available! Contact us to find what you can save.
This product comes from: China.
Typical lead time: 14-21 working days.
Contact us for more accurate information.
  • Further Information
  • Documents
  • Show All

Further Information

Application:
FLIA Kit for Antigen Detection.
Assay length:
3h
Assay procedure summary:
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100uL standard or sample to each well,
    add 10uL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100uL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100uL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100uL sheath solution, swirl for 2 minutes, read on the machine.
Detection range:
4.883-5000pg/mL
Method:
Double-antibody Sandwich
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level of the target, etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level of the target, etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100, Intra-Assay: CV<10%, Inter-Assay: CV<12%
Sample type:
tissue homogenates, cell lysates and other biological fluids
Sensitivity:
The minimum detectable dose of this kit is typically less than 1.628pg/mL
Specificity:
This assay has high sensitivity and excellent specificity for detection of the target ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between the target ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test principle:
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.
Uniprot:
Q8C6L5